472 / 750 page ![]() Section 12 Serial Communication Interface Rev.6.00 Jun. 03, 2008 Page 424 of 698 REJ09B0074-0600 12.6.4 Serial Data Reception (Clocked Synchronous Mode) Figure 12.21 shows an example of SCI operation for reception in clocked synchronous mode. In serial reception, the SCI operates as described below. 1. The SCI performs internal initialization synchronous with a synchronous clock input or output, starts receiving data, and stores the received data in RSR. 2. If an overrun error occurs (when reception of the next data is completed while the RDRF flag in SSR is still set to 1), the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt request is generated, receive data is not transferred to RDR, and the RDRF flag remains to be set to 1. 3. If reception is completed successfully, the RDRF bit in SSR is set to 1, and receive data is transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is generated. Continuous reception is possible because the RXI interrupt routine reads the receive data transferred to RDR before reception of the next receive data has finished. Bit 7 Serial data Synchronization clock 1 frame RDRF ORER ERI interrupt request generated by overrun error RXI interrupt request generated RDR data read and RDRF flag cleared to 0 in RXI interrupt service routine RXI interrupt request generated Bit 0 Bit 7 Bit 0 Bit 1 Bit 6 Bit 7 Figure 12.21 Example of SCI Operation in Reception Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the ORER, FER, PER, and RDRF bits to 0 before resuming reception. Figure 12.22 shows a sample flow chart for serial data reception. When the internal clock is selected during reception, the synchronization clock will be output until an overrun error occurs or the RE bit is cleared. To receive data in frame units, a dummy data of one frame must be transmitted simultaneously. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |