Back Button SS72012 Datasheet HTML 120Page - Amphenol CIT. SS72012 Datasheet HTML 121Page - Amphenol CIT. SS72012 Datasheet HTML 122Page - Amphenol CIT. SS72012 Datasheet HTML 123Page - Amphenol CIT. SS72012 Datasheet HTML 124Page - Amphenol CIT. SS72012 Datasheet HTML 125Page - Amphenol CIT. SS72012 Datasheet HTML 126Page - Amphenol CIT. SS72012 Datasheet HTML 127Page - Amphenol CIT. SS72012 Datasheet HTML 128Page - Amphenol CIT. Next Button
Zoom Inzoom in Zoom Outzoom out
 124 / 144 page
background image
120
Aerospace | Military | Transportation | Industrial | Specialty
Glossary
Braid Angle: The angle between the axis of the cable and axis of any
one member or strand of the braid (also known as angle of advance).It
is further the smaller of the two angles formed by the carrier and the
longitudinal axis of the braid.
Braid Carrier: The bobbin on a braiding machine which holds one
group of strands or filaments consisting of a specific number of ends.
The carrier revolves during the braiding operation
Braid Ends: The strands used to make up one carrier.The strands are
wound side by side on the carrier bobbin and lay parallel in the finished
braid.
Breakdown: A disruptive electrical discharge through the insulation.
Breakdown Voltage: The voltage at which the insulation between
two conductors will break down.
Breakout: The point at which a conductor or conductors break out
from a multi-conductor cable to complete circuits at various points
along the main cable.The remaining conductors continue on within the
jacket.
B & S: Brown & Sharpe Gage, a wire diameter standard.Same as AWG.
Building Wire: Insulated wires used in buildings for light and power.
600 V or less.Usually not exposed to outdoor environment.
Bunched Stranding: Terms applied to group of strands twisted
together in a random manner in the same direction in one operation
without regard to geometric arrangements of specific strands.
Bus: A common point for electrical circuits to return.
Bus Bar: A heavy copper (or other metal such as aluminum) strip or
bar used inside switchboards, power plants, and main panels to carry
heavy currents.
Bus Wire: Wire used to connect two terminals inside an electrical unit.
Butt Joint: Joining of two conductors end-to-end, with no overlap and
with their axes in line.
"C" (cured) Stage (of resin): The condition of a resin polymer when it
is in the solid state, with high molecular weight, being insoluble and
infusible.
Cable: Either a stranded conductor with or without insulation and
other covering (single-conductor cable), or a combination of
conductors insulated from one another (multiple-conductor cable).
Cable Assembly: A cable with connectors on one or both ends.
Cable Core: The portion of an insulated cable lying under the
protective covering or coverings.In coaxial cables, the center conductor
and dielectric.
Cable Core Binder: A wrapping of tapes or cords around the several
conductors of a multiple-conductor cable used to hold them together.
Usually supplemented by an outer covering of braid, jacket, or sheath.
Cable Filler: The material used in multiple-conductor cables to occupy
the interstices formed by the assembly of the insulated conductors,
thus forming a cable core of the desired shape (usually circular).
Cable Sheath: The protective covering applied to cables.
Cabling: Twisting together two or more insulated conductors by
machine to form a cable.This also is a term loosely applied to bundling
of wires together such as in the forming of wire harnesses.
Cable Factor: Used in a formula for calculating the overall diameter of
cables:D=fd where D=cable diameter, f=factor, and d=diameter of
one conductor.
Capacitance: That property of a system of conductors and dielectrics
which permits the storage of electricity when potential difference
exists between the conductors.Its value is expressed as the ratio of a
quantity of electricity to a potential difference.A capacitance value is
always positive.
Capacitive Coupling: Electrical interaction between two conductors
caused by the mutual capacitance between them.
Carrier: The basic woven element of a braid consisting of one or more
ends (strands) which creates the interlaced effect.
Cellular Insulation: Material in foamed form with the cells either
closed or open (interconnected).
Characteristic Impedance (Z0): The impedance of a circuit that,
when connected to the output terminals of a uniform transmission line
(such as a coaxial cable) of arbitrary length, causes the line to appear
infinitely long.A uniform line terminated in its characteristic
impedance will have no standing waves, no reflections from the end,
and a constant ratio of voltage to current at a given frequency at every
point on the line.
Cigarette Wrap: Tape insulation wrapped longitudinally instead of
spirally over a conductor.
Circuit: A complete path over which electrons can flow from the
negative terminals of a voltage source through parts and wires to the
positive terminals of the same voltage source.
Circular Mil: A unit of area equal to the area of a circle whose
diameter is 1 mil (0.001 inch); equal to (square mil x .7854).Used
chiefly in specifying cross-sectional areas of round conductors.
Cladding: A method of applying a layer of metal over another metal
whereby the junction of the two metals is continuously welded.Clad
wires have a thicker layer of the covering metal than plated wires.
Closed Cell: Foamed or cellular material with cells which are not
interconnected.
Coating: Plating the surface of a conductor to prevent corrosion and
facilitate soldering.In wire terminology,“coated”is often used
interchangeably with“plated.”Term can also apply to an insulating
coating.
Coaxial Cable: A cable consisting of two cylindrical conductors with a
common axis, one inside the other.The two conductors are separated
by a dielectric.The outer conductor, normally at ground-potential, acts
as a return path for current flowing through the center conductor and
prevents energy radiation from the cable.The outer conductor, or shield,
is also used to prevent external radiation from affecting the current
flowing in the inner conductor.The outer shield or conductor can
consist of braided strands of round or flat wire, or a solid metal tube.
Coil Effect: The inductive effect caused by a spiral-wrapped shield;
more pronounced at higher frequency.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com