Back Button SS72012 Datasheet HTML 121Page - Amphenol CIT. SS72012 Datasheet HTML 122Page - Amphenol CIT. SS72012 Datasheet HTML 123Page - Amphenol CIT. SS72012 Datasheet HTML 124Page - Amphenol CIT. SS72012 Datasheet HTML 125Page - Amphenol CIT. SS72012 Datasheet HTML 126Page - Amphenol CIT. SS72012 Datasheet HTML 127Page - Amphenol CIT. SS72012 Datasheet HTML 128Page - Amphenol CIT. SS72012 Datasheet HTML 129Page - Amphenol CIT. Next Button
Zoom Inzoom in Zoom Outzoom out
 125 / 144 page
background image
121
Aerospace | Military | Transportation | Industrial | Specialty
Glossary
Cold Bend: Test procedure in which a sample of wire or cable is wound
around a mandrel of a specified size within a cold chamber, at a
specified temperature for a given number of turns at a given rate of
speed.The sample is then removed and examined for defects or
deterioration in the materials or construction.
Cold Flow: Permanent deformation of materials due to mechanical
force or pressure.
Cold Joint: Defective solder joint due to insufficient heating.
Cold Work: Hardening and embrittlement of metal due to repeated
flexing action.Also known as work hardening or metal fatigue.
Color Code: A color system for wire or circuit identification by use of
solid-colored insulation or stripes, tracers, braids, surface printing, etc.
Compact Conductor: Stranded conductor which is rolled to deform
the round wires, forcing them to fill the normal interstices between
the wires within the conductor.
Composite (Clad) Wire: A wire having a core of one metal with a
fused outer shell of one or more different metals.
Composite Conductor: Two or more strands of different metals,
assembled and operated in parallel.
Compound: An insulating or jacketing material made by mixing two
or more ingredients resulting in one material.
Concentric-Lay Conductor: A stranded conductor with a central core
surrounded by one or more layers of helically wound strands in a fixed
round geometric arrangement.Most commonly, all wires are of the
same size and the central core is a single wire.The direction of lay for
successive layers may be alternately reversed or in the same direction.If
the direction of lay for successive layers is the same, the lay length will
increase with each successive layer.The stranded direction of the outer
layer is left hand.
Concentric-Lay Cable:Either a concentric-lay conductor as defined
above, or a multiple-conductor cable composed of a central core
surrounded by one or more layers of helically-laid wires.
Concentric Strand: A strand that consists of a central wire or core
surrounded by one or more layers of spirally laid wires.Each layer after
the first has six more strands than the preceding layer and is applied in
a direction opposite to that of the layer underneath.
Concentricity: In a wire or cable, the measurement of the location of
the center of the conductor with respect to the geometric center of the
outer layer.
Conductance: The reciprocal of resistance.It is the ratio of current
passing through a material to the potential difference at its ends.
Conductivity: Reciprocal of volume resistivity.Conductance of a unit
cube of any material.
Conductor: A wire or combination of wires not insulated from one
another, suitable for carrying electric current.
Continuity Test: A test performed on a length of finished wire or
cable to determine if the electrical current flows continuously
throughout the length.
Continuous Vulcanization: The process of vulcanizing wire
insulation after extrusion onto a conductor by passing it through a
vulcanizing chamber under high pressure and temperature.
Contrahelical: The layer spiraling in a direction opposite that of the
preceding layer within a wire or cable.
Control Cable: A cable used for remote control operation of
equipment.
Controlled Impedance Cable:Cable with two or more insulated
conductors where impedance between respective conductors is kept
constant throughout the entire length.
Copolymer: A compound resulting from the chemical reaction of two
chemically different monomers.
Copper: Copper and copper alloys are the most widely-used metals in
wire and cable conductors because of their high electrical and thermal
conductivity, excellent corrosion resistance, and ease of fabricating,
joining and forming.Some of the common types of electrical coppers
and copper alloys are:
• Electrolytic tough pitch copper (ETPC) has a minimum copper content
of 99.9%.Annealed conductivity averages 101% with a 100%
minimum.It is widely used for wire and bus bars.
• Silver bearing copper with a 99.9% copper content provides nearly
the same electrical conductivity as ETP copper but offers a higher
softening point, greater resistance to creep, and higher strength at
elevated temperatures.
• Oxygen-free high conductivity copper (OFHC) has 99.95% minimum
copper content with an average annealed conductivity of 101%.This
copper has no residual deoxidant.Other coppers use phosphorus,
boron, or lithium as deoxidizers to eliminate susceptibility to hydrogen
embrittlement and improve weldability.
Copper-Constantan: Thermocouple wire with one copper and one
constantan wire.The copper is the positive wire and the constantan is
the negative wire.Constantan is an alloy of copper, nickel, manganese,
and iron.
Copper-Covered Steel Wire: A wire having a steel core to which is
fused an outer shell of copper.Also known as“copperweld.”
Cord: A small, very flexible insulated cable constructed to withstand
mechanical abuse.(Note:There is no sharp dividing line in respect to
size between a cord a cable, but generally, a cord is considered to be 10
AWG and smaller.)
Cord sets: Portable cords fitted with any type of wiring device at one
or both ends.
Core: A component or assembly of components over which other
materials are applied, such as shield, sheath, or armor.In coaxial cables,
the core consists of the center conductor and dielectric.
Corona: The phenomenon of air breakdown when electric stress at the
surface of a conductor exceeds a certain value.At higher values, stress
results in luminous discharge.
Corona Extinction: The voltage at which corona, once initiated, will
extinguish as voltage is decreased.
Corona Ignition Point: The voltage at which corona will initiate as
voltage is increased.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com