221 / 274 page ![]() Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family 9–63 Configuration Features August 2012 Altera Corporation Cyclone III Device Handbook Volume 1 ■ To allow the controllers to properly recognize a successful JTAG programming that results in the device reaching user mode The ACTIVE_DISENGAGE instruction is required before JTAG programming regardless of the current state of the Cyclone III device family if the MSEL pins are set to an active configuration scheme (AS or AP). If the ACTIVE_DISENGAGE instruction is issued during a passive configuration scheme (PS or FPP), it has no effect on the Cyclone III device family. Similarly, the CONFIG_IO instruction is issued after an ACTIVE_DISENGAGE instruction, but is no longer required to properly halt configuration. Table 9–20 lists the required, recommended, and optional instructions for each configuration mode. The ordering of the required instructions is a hard requirement and must be met to ensure functionality. In AS or AP configuration schemes, the ACTIVE_DISENGAGE instruction puts the active configuration controllers into idle state. If a successful JTAG programming is executed, the active controllers are automatically re-engaged after user mode is reached using JTAG programming. This causes the active controllers to transition to their respective user mode states. If JTAG programming fails to get the Cyclone III device family to enter user mode and re-engage active programming, there are available methods to achieve this for the AS or AP configuration schemes: ■ When in the AS configuration scheme, you can re-engage the AS controller by moving the JTAG TAP controller to the reset state or by issuing the ACTIVE_ENGAGE instruction. ■ When in the AP configuration scheme, the only way to re-engage the AP controller is to issue the ACTIVE_ENGAGE instruction. In this case, asserting the nCONFIG pin does not re-engage either active controller. Table 9–20. JTAG Programming Instruction Flows (1) JTAG Instruction Configuration Scheme and Current State of the Cyclone III Device Prior to User Mode (Interrupting Configuration) User Mode Power Up PS FPP AS AP (2) PS FPP AS AP (2) PS FPP AS AP (2) FACTORY NA NA NA NA NA NA NA NA R R R NA ACTIVE_DISENGAGE OO R R O O O R O O R R CONFIG_IO Rc Rc O O O O O O NA NA NA NA Other JTAG instructions O O O O O O O O O O O O JTAG_PROGRAM RR R R R R R R R R R R CHECK_STATUS Rc Rc Rc Rc Rc Rc Rc Rc Rc Rc Rc Rc JTAG_STARTUP RR R R R R R R R R R R JTAG TAP Reset/ other instruction R R R R R R R R R R R R Notes to Table 9–20: (1) “R” indicates that the instruction is required to be executed before the next instruction, “O” indicates the optional instruction, “Rc” indicates the recommended instruction, and “NA” indicates that the instruction is not allowed to be executed in this mode. (2) AP configuration is for Cyclone III devices only. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |