581 / 1071 page ![]() Section 14 IEBus™ Controller (IEB) [H8S/2258 Group] Rev. 5.00 Aug 08, 2006 page 495 of 982 REJ09B0054-0500 (2) Data Command Transfer (Control Bits: Read (H'3, H'7), Write (H'A, H'B, H'E, H'F)) In the case of data read (H'3, H'7), data in the data buffer of the slave unit is read in the master unit. In the case of data write (H'B or H'F) or command write (H'A or H'E), data received in the slave unit is processed in accordance with the operation specification of the slave unit. Notes: 1. The user can select data and commands freely in accordance with the system. 2. H'3, H'A, or H'B may lock depending on the communications condition and status. (3) Locked Address Read (Control Bits: H'4, H'5) In the case of the locked address read (H'4 or H'5), the address (12 bits) of the master unit which issues lock instruction is configured in bytes shown in figure 14.4. MSB Lower 8 bits Undefined Control bits: H'4 Control bits: H'5 Upper 4 bits LSB Figure 14.4 Locked Address Configuration (4) Locking/Unlocking (Control Bits: Setting (H'3, H'A, H'B), Cancellation: (H'6)) The lock function is used for message transfer over multiple communications frames. Locked unit receives data only from the unit which has locked. Locking and unlocking are described below. • Locking When the acknowledge bit of 0 in the message length field is transmitted/received with the control bits indicating the lock operation, and then the communications frame is completed before completion of data transmission/reception for the number of bytes specified by the message length bits, the slave unit is locked by the master unit. In this case, the bit (bit 2) relevant to lock in the byte data indicating the slave status is set to 1. Lock is set only when the number of data exceeds the maximum number of transfer bytes in one frame. Lock is not set by other error termination. • Unlocking When the control bits indicate the lock (H'3, H'A, or H'B) or unlock (H'6) operation and the byte data for the number of bytes specified by the message length bits are transmitted/received |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |