| Motore di ricerca datesheet componenti elettronici |
|
H8S/2224 Scheda tecnica(PDF) 612 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
H8S/2224 Scheda tecnica(HTML) 612 Page - Renesas Technology Corp |
|
612 / 1071 page ![]() Section 14 IEBus™ Controller (IEB) [H8S/2258 Group] Rev. 5.00 Aug 08, 2006 page 526 of 982 REJ09B0054-0500 Bit Bit Name Initial Value R/W Description 1 DLE 0 R/W Overflow of Maximum Number of Receive Bytes in One Frame Indicates that the maximum number of bytes defined by communications mode have been received because a parity error or overrun error occurred, or that the reception has not be completed because the message length value exceeds the maximum number of receive bytes in one frame. The IEB sets the RxE flag and enters the wait state. [Setting condition] When the reception has not been completed although the maximum number of bytes defined by communications mode have been received. [Clearing condition] When writing 0 after reading DLE = 1 0 PE 0 R/W Parity Error Indicates that a parity error has occurred during data field reception. If a parity error occurs before data field reception, the IEB immediately enters the wait state and the PE flag is not set. If a parity error occurs when the maximum number of receive bytes in one frame has not been received, the PE flag is not set. When a parity error occurs, the IEB returns a NAK to the communications destination unit via the acknowledge bit. In this case, the communications destination unit continues retransfer up to the maximum number of receive bytes in one frame and if the reception has been completed normally by clearing the parity error, the PE flag is not set. If the parity error is not cleared when the reception is terminated before receiving data for the number of bytes specified by the message length, the PE flag is set. In broadcast reception, if a parity error occurs during data field reception, the IEB enters the wait state immediately after setting the PE flag. [Setting condition] When the parity bit of last data of the data field is not correct after the maximum number of receive bytes has been received [Clearing condition] When writing 0 after reading PE = 1 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |