Back Button H8S/2224 Datasheet HTML 624Page - Renesas Technology Corp H8S/2224 Datasheet HTML 625Page - Renesas Technology Corp H8S/2224 Datasheet HTML 626Page - Renesas Technology Corp H8S/2224 Datasheet HTML 627Page - Renesas Technology Corp H8S/2224 Datasheet HTML 628Page - Renesas Technology Corp H8S/2224 Datasheet HTML 629Page - Renesas Technology Corp H8S/2224 Datasheet HTML 630Page - Renesas Technology Corp H8S/2224 Datasheet HTML 631Page - Renesas Technology Corp H8S/2224 Datasheet HTML 632Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 628 / 1071 page
background image
Section 14 IEBus™ Controller (IEB) [H8S/2258 Group]
Rev. 5.00 Aug 08, 2006 page 542 of 982
REJ09B0054-0500
14.6.3
RxRDY Flag and Overrun Error
1. The RxRDY flag indicates that IERBR stores data. Reading from IERBR by the DTC clears
the RxRDY flag. Meanwhile, the RxRDY flag must be cleared by software since reading from
IERBR by the CPU does not clear the RxRDY flag.
2. If the CPU fails to read from IERBR by the timing of the frame reception or if the number of
transfer words is less than the length specified by the message length bits, an overrun error
occurs.
3. The IEB receives data while the RxRDY flag is set and sets the OVE flag when the parity bit
reception starts. If the OVE flag is set when the acknowledge bit is transmitted, the IEB
assumes that an overrun error has occurred, returns a NAK, and discards the data in the receive
shift register.
4. On the transmit side, the unit continues retransfer until an ACK is received because it receives
a NAK.
5. If the OVE flag is cleared without loading the receive data from IERBR in the RxE interrupt
handling routine caused when the OVE flag is set to 1, the IEB decides that the overrun error
has been cleared and sends an ACK to other units. In this case, the transmit unit completes the
communications correctly. However, no receive data is loaded from the IERBR and the receive
unit continues reception. Accordingly, in an interrupt handling routine caused by the OVE flag,
receive data must be loaded from IERBR, the RxRDY flag must be cleared. The DTC, thus,
should be ready to receive the next byte, and then the OVE flag must be cleared.
6. Item 5 above will not occur when the DTC transfer words is specified as the IERBFL value.
14.6.4
Error Flag s in the IETEF
(1) AL Flag
The AL Flag is set to 1 when arbitration is lost even if retransfer is performed for the number of
times specified by IEMCR after arbitration has been lost. The AL flag is not set when arbitration is
won during retransfer. If the AL flag is set to 1, the TxE flag is set and the wait state is entered.
(2) UE Flag
If the UE flag is set to 1, the TxE flag is set and the wait state is entered. For details, see section
14.6.2, TxRDY Flag and Underrun Error.
(3) TTME Flag
If a timing error occurs during data transfer, the TTME and TxE flags are set, and the wait state is
entered.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com