| Motore di ricerca datesheet componenti elettronici |
|
L99H92 Scheda tecnica(PDF) 45 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99H92 Scheda tecnica(HTML) 45 Page - STMicroelectronics |
|
45 / 77 page ![]() 5.15 Operating modes Figure 25. Operating modes GADG120920221140SA Active mode Standby mode Fail-safe mode EN low or VDD≤VDDPOR_ON or VS≤VSPOR_ON Charge pump OFF Registers content lost Gate drivers off Charge pump ON Gate drivers forced in sink switch mode OUTE control bit reset and forced to zero EN high, VDD>VDDPOR_OFF, VS>VSPOR_OFF FSINB pin high with FSIN_HS1=FSIN_LS1= FSIN_HS2=FSIN_LS2 = 0 (FSIN status bit reset to 0), WDGF status flag set to 0 FSINB pin low (FSIN status bit set to 1 or WDGF status flag set to 1 OUTE = 0, OLH1L2 = 1 and/or OLH2L1=1 (note) Off state diagnostic mode OUTE = 1 or OLH1L2 = OLH2L1=0 Charge pump ON, Gate driver OFF Active mode includes faulty states. Gate drivers and charge pump are ON/OFF according to the diagnostic table EN low or VDD≤VDDPOR_ON or VS≤VSPOR_ON EN low or VDD≤VDDPOR_ON or VS≤VSPOR_ON Note: To achieve the device minimum current consumption in standby mode, the EN pin has to be pulled low. Table 41. Diagnostic table Event Status register flag/bit Global status byte bit Device actions DIAGN pin behavior VDH overvoltage VDHOV DE Active switch-off of external LS MOSFETs with maximum available gate current (LS gate drivers forced in sink switch mode). Active switch-off of external HS MOSFETs with maximum available gate current for 32 µs up to 64 µs and as long as VCP>VDH+3 V, followed by passive/resistive turn off. Charge-pump switched off Pulled low if DGVDHOVE is set VDH undervoltage VDHUV DE Active switch-off of external LS MOSFETs with maximum available gate current (LS gate drivers forced in sink switch mode). Active switch-off of external HS MOSFETs with maximum available gate current as long as VCP>VDH+3V, otherwise passive/resistive turn off. Pulled low if DGVDHUVE is set VS overvoltage Warning VSOVW GW None Pulled low if DGVSOVWE is set VDD overvoltage VDDOV DE Active switch-off of all external MOSFETs with maximum available gate current (all gate drivers forced in sink switch mode). Pulled low if DGVDDOVE is set Thermal warning TW GW None Pulled low if DGTWE is set Thermal shutdown TSD DE Active switch-off of external LS MOSFETs with maximum available gate current (LS gate drivers forced in sink switch mode). Active switch-off of external HS MOSFETs with maximum available gate current for 32 µs up to 64µs and as long as VCP>VDH+3 V, followed by passive/resistive turn off. Charge-pump switched off. Pulled low if DGTSDE is set L99H92 Operating modes DS14069 - Rev 4 page 45/77 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |