11 / 77 page ![]() Figure 5. Full-bridge GSHx and GSLx slopes GADG190920221238SA VGSyx y= H, L x= 1, 2 VDSyx y= H, L x= 1, 2 2.6.3 Short circuit detection / drain-source monitoring (DSHS/DSLS) The voltage-drop over each MOSFET is sensed and compared to a programmable threshold to detect an overcurrent condition. This monitoring is active only on the MOSFETs driven to be turned on. In dual half-bridge mode, each half-bridge has its own programmable threshold (DSMONx[2:0]), blanking time (DSBTx[2:0]) and filtering time (FTx[1:0]). As soon as the gate driver starts to turn on a MOSFET, the corresponding drain source monitoring comparator output is masked for the programmed blanking time to give time to the MOSFET to turn on. Besides the blanking time, a filtering time is also present to filter noise. Both values have to be chosen depending on the application. If the voltage-drop over the driven MOSFET exceeds the programmed threshold voltage VSCdx (DSMON1[2:0] control bits for full-bridge or leg 1 and DSMON2[2:0] control bits for leg 2 in dual half-bridge mode) for a time longer than the programmed filtering time (and the programmed blanking time, where applicable), then: • with DSMON_CONFIG control bit set to zero the gate drivers belonging to the faulty leg are forced in sink switch mode to switch off actively the half-bridge MOSFETs with the maximum available current, regardless of the programmed gate discharge current (SLEWDx control bits) • for INPMODE set to zero and DSMON_CONFIG control bit set to one all the gate drivers are forced in sink switch mode to switch off actively all the full-bridge MOSFETs. In any case, the drain source monitoring flag DSHSx or DSLSx of the MOSFET detecting the fault is set. The drain-source monitoring flags have to be cleared through SPI to reactivate the affected half-bridge/full-bridge gate drivers that are forced in sink switch mode. The drain-source monitoring flag DSHSx/DSLSx can be cleared by an SPI “Read & Clear” command only if the fault condition is no longer present. L99H92 Gate drivers DS14069 - Rev 4 page 11/77 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |