137 / 212 page ![]() 137 4109J–8051–10/06 AT8xC51SND1C Figure 17-9. Data Frame Format (Mode 1) 17.4.0.2 Modes 2 and 3 Modes 2 and 3 are full-duplex, asynchronous modes. The data frame (see Figure 17-10) con- sists of 11 bits: one start bit, eight data bits (transmitted and received LSB first), one programmable ninth data bit and one stop bit. Serial data is transmitted on the TXD pin and received on the RXD pin. On receive, the ninth bit is read from RB8 bit in SCON register. On transmit, the ninth data bit is written to TB8 bit in SCON register. Alternatively, you can use the ninth bit can be used as a command/data flag. Figure 17-10. Data Frame Format (Modes 2 and 3) 17.4.1 Transmission (Modes 1, 2 and 3) To initiate a transmission, write to SCON register, set the SM0 and SM1 bits according to Table 113, and set the ninth bit by writing to TB8 bit. Then, writing the Byte to be transmitted to SBUF register starts the transmission. 17.4.2 Reception (Modes 1, 2 and 3) To prepare for reception, write to SCON register, set the SM0 and SM1 bits according to Table 113, and set the REN bit. The actual reception is then initiated by a detected high-to-low transition on the RXD pin. 17.4.3 Framing Error Detection (Modes 1, 2 and 3) Framing error detection is provided for the three asynchronous modes. To enable the framing bit error detection feature, set SMOD0 bit in PCON register as shown in Figure 17-11. When this feature is enabled, the receiver checks each incoming data frame for a valid stop bit. An invalid stop bit may result from noise on the serial lines or from simultaneous transmission by 2 devices. If a valid stop bit is not found, the software sets FE bit in SCON register. Software may examine FE bit after each reception to check for data errors. Once set, only soft- ware or a chip reset clear FE bit. Subsequently received frames with valid stop bits cannot clear FE bit. When the framing error detection feature is enabled, RI rises on stop bit instead of the last data bit as detailed in Figure 17-17. Figure 17-11. Framing Error Block Diagram Mode 1 D0 D1 D2 D3 D4 D5 D6 D7 Start bit 8-bit data Stop bit D0 D1 D2 D3 D4 D5 D6 D8 Start bit 9-bit data Stop bit D7 SM0 1 0 SMOD0 PCON.6 SM0/FE SCON.7 Framing Error Controller FE |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |