| Motore di ricerca datesheet componenti elettronici |
|
TMP89FS60 Scheda tecnica(PDF) 90 Page - Toshiba Semiconductor |
|
|
|||||||||||||||||||||||||||||
TMP89FS60 Scheda tecnica(HTML) 90 Page - Toshiba Semiconductor |
|
90 / 410 page ![]() Page 76 5. Watchdog Timer (WDT) 5.3 Functions TMP89FS60 RA000 Note:The 8-bit up counter source clock operates out of synchronization with WDCTR<WDTEN>. Therefore, the first overflow time of the 8-bit up counter after WDCTR<WDTEN> is set to "1" may get shorter by a maximum of 1 source clock. The 8-bit up counter must be cleared within the period of the overflow time minus 1 source clock cycle. 5.3.2 Setting the clear time of the 8-bit up counter WDCTR<WDTW> sets the clear time of the 8-bit up counter. When WDCTR<WDTW> is "00", the clear time is equal to the overflow time of the 8-bit up counter, and the 8-bit up counter can be cleared at any time. When WDCTR<WDTW> is not "00", the clear time is fixed to only a certain period within the overflow time of the 8-bit up counter. If the operation for releasing the 8-bit up counter is attempted outside the clear time, a watchdog timer interrupt request signal occurs. At this time, the watchdog timer is not cleared but continues counting. If the 8-bit up counter is not cleared within the clear time, a watchdog timer reset request signal or a watchdog timer interrupt request signal occurs due to the overflow, depending on the WDCTR<WDTOUT> setting. Figure 5-3 WDCTR<WDTW> and the 8-bit up Counter Clear Time 5.3.3 Setting the overflow time of the 8-bit up counter WDCTR<WDTT> sets the overflow time of the 8-bit up counter. When the 8-bit up counter overflows, a watchdog timer reset request signal or a watchdog timer interrupt request signal occurs, depending on the WDCTR<WDTOUT> setting. If the watchdog timer interrupt request signal is selected as the malfunction detection signal, the watchdog counter continues counting, even after the overflow has occurred. The watchdog timer temporarily stops counting up in the STOP mode (including warm-up) or in the IDLE/ SLEEP mode, and restarts counting up after the STOP/IDLE/SLEEP mode is released. To prevent the 8-bit up counter from overflowing immediately after the STOP/IDLE/SLEEP mode is released, it is recommended to clear the 8-bit up counter before the operation mode is changed. Table 5-1 Watchdog Timer Overflow Time (fcgck=8.0 MHz; fs=32.768 kHz) WDTT Watchdog timer overflow time [s] NORMAL mode SLOW mode DV9CK = 0 DV9CK = 1 00 32.77 m 62.50 m 62.50 m 01 131.07 m 250.00 m 250.00 m 10 524.29 m 1.000 1.000 11 2.097 4.000 4.000 When WDCTR<WDTW> is 00 8-bit up counter value When WDCTR<WDTW> is 01 When WDCTR<WDTW> is 10 When WDCTR<WDTW> is 11 00H 01H 3FH 40H 7FH 80H BFH C0H FFH 00H FFH Clear time Clear time Outside the clear time Clear time Outside the clear time Clear time Outside the clear time |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |