| Motore di ricerca datesheet componenti elettronici |
|
AD9546/PCBZ Scheda tecnica(PDF) 90 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9546/PCBZ Scheda tecnica(HTML) 90 Page - Analog Devices |
|
90 / 205 page ![]() AD9546 Data Sheet Rev. 0 | Page 90 of 205 tCARRIER (8 + x) × tCARRIER K × (8 + x) × tCARRIER tGRID Figure 65. Grid Timing Diagram DEMODULATOR SYNCHRONIZATION The demodulators expect modulation events to occur at regular periodic intervals, tGRID, with tGRID comprising an integer number of tCARRIER periods (see Figure 65) such that tGRID = K × (8 + x) × tCARRIER where: K is an integer K ≥ 1. x is an integer with x ≥ 0. Essentially, the value of x relates to the divide ratio, R, of the reference divider as follows: R = 8 + x The net effect is that the reference divider produces an output clock of period, tCARRIER × (8 + x). The reference TDC time stamps the rising edge of each divider output clock cycle with K time stamps occurring in each tGRID period. When the demodulator identifies a modulation event within the carrier signal, it generates a demodulator clock pulse with timing according to Figure 64. The demodulator clock pulse synchronizes the reference divider and causes the reference TDC to tag the associated time stamp (see Figure 62), which creates a fixed timing relationship between incoming modula- tion events and the occurrence of tagged time stamps. Specifically, every Kth time stamp (see Figure 65) is a tagged time stamp. The demodulator denotes the next rising edge of the carrier following the modulation event as the base edge. The user can set the timing of the demodulator clock pulse to occur a predefined number of tCARRIER periods after the base edge via the 2-bit unsigned bit field comprising Bits[5:4] in Register M per the register legend in Figure 62. The decimal value of this bit field, 0 (default), 1, 2, or 3, corresponds to the desired synchronization edge in Figure 64. The user must program a bit field value other than the default value of zero (Bits[5:4] = 0 is not supported). If a modulation event occurs off grid or the modulation rate changes to a new tGRID period, the demodulator must resynchronize. The demodulator requires at least three tCARRIER periods (including the first modulated cycle) to resynchronize when Bit 6 in Register M per the register legend in Figure 62 is Logic 0 and at least eight tCARRIER periods when Bit 6 is Logic 1. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |